null google.com, pub-0015564483429508, DIRECT, f08c47fec0942fa0

Gilson 200mm Sieve, All Stainless, Full Height, 200U

Price $95.98
Sieve Frame Diameter:
200mm
ISO Opening Size:
200 micrometer
Material:
All Stainless Steel
Frame Height:
Full Height
upsell:
/200mm-sieve-pan-stainless-full-height/
upsell:
/200mm-sieve-cover-stainless/
upsell:
/sieve-shaker-for-use-with-8-10-and-12-sieves-digital/
Mesh Size Range:
Medium
Condition:
New
Minimum Purchase:
1 unit
SKU:
V015.V200SF 200U

FREE SHIPPING (Continental US) | Estimated ship in 4-7 business days
* Estimate is for US customers only.
* Shipping and Import Duties are calculated at checkout.
See Product Information

Frequently Bought Together

Please choose Options for all selected Products

200mm All Stainless Full Height ISO Test Sieves

Our 200mm diameter ISO Test Sieves meet ISO 565 and 3310-1 specifications for Compliance Sieves, and are in stock for immediate delivery. We offer all ISO 565 mesh sizes available. Every ISO sieve is fitted with a rubber O-ring for a dust-free seal when nested in a sieve stack. Many ISO opening sizes and tolerances are equivalent to ASTM E11 sizes.

Our ISO Sieves are available with stainless steel frames and mesh, or brass frames with stainless steel mesh in full height or half height sizes. High-quality all-stainless steel sieves offer long service life and reduce specimen contamination. ISO Test sieves are available with full height or half height frames. Half height frames allow more sieves to be used in a stack.

Sample volume and particle size determine proper frame diameter and height. Material is processed more efficiently and accurately on a sieve with more surface area, and blinding is reduced. The thickness of a specimen fraction on the mesh of a sieve should be no more than a couple of particles or layers deep. Frame height must permit proper agitation of the specimen, allowing larger particles enough room to reorient to the mesh surface.

Our ISO Compliance sieves are supplied with a serial number and Compliance certificate. The certificates do not verify measurements of an individual sieve, but that the wire cloth and manufacturing methods comply with ISO requirements.

200mm diameter ISO Test Sieve has stainless steel woven-wire cloth with 200µm openings and full height stainless steel frame. Each sieve is individually serial numbered. Overall height is 2-5/8in and stacked height is 2-1/8in.

Features:

  • Individually serial numbered
  • Compliant with ISO 565, 3310-1 requirements for Compliance Sieves

Included Items:

  • 200mm Sieve, All Stainless, Full Height, 200µm
  • Certificate of Conformance to ISO 565, 3310-1 requirements

Accessories:

  • Sieve Pans - nest underneath sieves to collect fines
  • Sieve Covers - prevent sample loss during agitation
  • Verification Services - provide NIST traceable documentation of opening sizes
  • Sieve Cleaning Brushes - ensure full recovery of specimens and proper care of sieves

Sieve Specifications

  • Sieve Frame Diameter: 200mm
  • Frame Height: Full Height
  • Stacked Frame Height: 2-1/8in
  • Overall Frame Height: 2-5/8in
  • Material: Stainless Steel Frame/Stainless Steel Cloth
  • ISO 565, 3310-1 Opening Size: 200µm
  • Backing Cloth Included: No
  • Estimated Shipping Weight: 2.0lb (0.91kg)

The Gilson 200mm Sieve, All Stainless, Full Height, 200U is a high-quality product that meets ISO 565 and 3310-1 specifications for Compliance Sieves. With a 200mm diameter and full height, this sieve is perfect for various applications and is in stock for immediate delivery.

We offer all ISO 565 mesh sizes available, ensuring that you can find the perfect sieve for your needs. Each ISO sieve is fitted with a rubber O-ring, providing a dust-free seal when nested in a sieve stack. Additionally, many ISO opening sizes and tolerances are equivalent to ASTM E11 sizes, making this sieve versatile and compatible with other testing equipment.

The Gilson 200mm Sieve is constructed with a stainless steel frame and mesh, or you can choose the brass frame with stainless steel mesh option. Both options offer long service life and reduce specimen contamination, ensuring accurate and reliable results. You can also choose between full height or half height frames, with half height frames allowing for more sieves to be used in a stack.

When selecting the appropriate frame diameter and height, you must consider the sample volume and particle size. Material is processed more efficiently and accurately on a sieve with more surface area, reducing blinding. The frame height must also permit proper agitation of the specimen, allowing larger particles enough room to reorient to the mesh surface.

To guarantee the quality of our product, each Gilson 200mm Sieve is supplied with a serial number and Compliance certificate. While the certificates do not verify measurements of an individual sieve, they ensure that the wire cloth and manufacturing methods comply with ISO requirements.

In addition to the sieve itself, we also offer a range of accessories to enhance your testing experience. These include sieve pans, sieve covers to prevent sample loss during agitation, verification services for NIST traceable documentation of opening sizes, and sieve cleaning brushes for proper care of your sieves.

With its reliable performance, accurate results, and a comprehensive range of accessories, the Gilson 200mm Sieve, All Stainless, Full Height, 200U is the perfect choice for your testing needs. Purchase yours today and experience the difference.

RECOMMENDED FOR YOU

Global Gilson V200SF 200U, 200mm Diameter Full Height Sieve, Stainless Frame, Stainless Cloth, 200 micrometer

Gilson 200mm Sieve, All Stainless, Full Height, 200U

[]