The Concrete thickness gauge measures concrete slab thickness without drilling. With this device you no longer need to drill, core, or excavate sites to determine concrete slab thickness. The CTG-2 is a nondestructive system for measuring the thickness and integrity of concrete slabs. The Concrete thickness gauge detects: voids, honeycomb areas, cracks and delamination.
It can be used on pavements, tunnel linings, walls and other plate-like structures using the Impact Echo principle. Easy-to-use, this unit requires no special knowledge or training— just follow the easy instructions and connect the unit to a user-provided Windows-based computer or tablet (not included) and start testing using the included WinCTG2 software.
Software Features:
- Olson’s WinCTG-2 Software is used for data acquisition and analysis.
- Report Capability: Use X and Y coordinates to set up a test grid. Generate a thickness summary table which can be exported to most spreadsheets in comma separated format. For greater accuracy, calibrate the unit at a location of known thickness to obtain the concrete velocity for the job.
NOTE: TABLET NOT INCLUDED.
Thickness Range: 3.2" to 6' (81mm to 1.8m)
Thick Mode Thickness Range: 20" to 6' (50.8cm to 1.8m)
Power: CR123A 3V Lithium battery
Frequency Resolution: 10Hz
Samples per Test: 4545
Sampling Rate: 45454 samples per second
Maximum Nyquist Frequency: 22700Hz
Cable Length: 3' (910mm)