Thermolyne FB1315M Benchtop Muffle Furnace, Max. Temp. 2012F, 1.3L 120V

Price $2,120.98
upsell:
/45ml-porcelain-crucibles-5-ct/
upsell:
/crucible-tongs-tapered/
Furnace Max Temperature:
1100C/2012F
Furnace Chamber Size:
79 cu.in. / 1.3 L
upsell:
/heat-resistant-gloves/
Condition:
New
Minimum Purchase:
1 unit
SKU:
V015.MF-1315

FREE SHIPPING (Continental US) | Estimated ship in 4-6 weeks
* Estimate is for US customers only.
* Shipping and Import Duties are calculated at checkout.
See Product Information

Frequently Bought Together

Please choose Options for all selected Products

Thermolyne FB1315M Benchtop Muffle Furnace, Max. Temp. 2012F, 1.3L 120V

The Thermolyne Muffle Furnace is used for ashing, ignition tests, gravimetric analyses, and volatile matter determinations. For construction materials, furnaces are used for tests of soils, aggregates, and cement. This unit has rugged components and top quality materials to assure longest service life.  The max. temp range for this furnace is 2012F (1100C) and has a chamber capacity is 76in3.

The standard digital control displays chamber temperature until the push to set temperature button is pressed. The display then indicates set-point temperature until released. The display shows actual temperature or set-point.

Muffle Furnace is a small benchtop style furnace with a 0.04ft³ (1.3L) capacity and a temperature range of 212–2,012°F (100–1,100°C).

This compact unit is equipped with a dual-display indicating temperature and setpoint, energy-saving ceramic fiber insulation for faster heating, heating elements on the top and sides to ensure uniform temperatures, and a drop-down door that also functions as a shelf when loading or unloading. The furnace also features a door safety switch that stops power to the heating elements when opened, a 0.38in (9.5mm) rear chamber port for monitoring temperatures, and thermocouple break protection.

Both models are designed for use in ashing, ignition tests, gravimetric analyses, and volatile matter determinations, as well as for testing test soils, aggregates, and cement. Each unit comes with a single setpoint controller, thermocouple, power cord, and hearth plate for protecting the bottom of the furnace.

Features:

  • Embedded heating elements for temperature uniformity
  • Made of rugged, durable components for long service life
  • Safety features for user protection

Also has multiple elements in sides, tops, and/or bottoms. Since doors and backs have no elements, only the center two-thirds of the chamber is considered uniform in temperature, and chamber size should be selected accordingly. This unit has a ceramic fiber insulation for faster heat-up and reduction of energy consumption. It is also equipped with safety interlock door switches. Power to the elements is automatically cut off when the door is opened. Supplied with a cord and plug.

Accessories:

  • Crucible Tongs to safely remove beakers and other labware from the furnace
  • Porcelain Crucibles used for loss-on-ignition testing of cement, fly ash, and soils and are available in 10, 30, or 45mL
  • Heat Resistant Gloves provide additional operator protection from high temperatures when placing or removing items inside the furnace

Thermo Scientific Furnaces [EU]

Specifications:

Capacity (English)       0.04 cu.ft.

Certifications/Compliance      CSA approved

Description     FB1315M

Capacity (Metric)        1.3 L

Temperature (Metric) 100C to 1100C

Type    Single Setpoint

Power Consumption   1060 w

Temperature Stability 0.3 at 1000C (7.8 at 1000C)

Dimensions (D x W x H) Interior         5 x 4 x 3.8 in. (13 x 10.3 x 9.8 cm)

Dimensions (L x W x H) Exterior         13 x 9 x 14 in. (33 x 23 x 36 cm)

Length (English)          13 in.

Length (Metric)           33 cm

Width (English)           4 in.

Width (Metric)            23

Width (Metric) Interior           10.3 cm

Height (English)           14 in.

Height (English) Interior         3.8 in.

Height (Metric)           36 cm

Height (Metric) Interior          9.8 cm

Depth (English) Interior          5 in.

Depth (Metric) Interior           13 cm

Electrical Requirements          120 V 50/60 Hz

Voltage            120 V

Frequency       50/60 Hz

View the full line of Thermolyne Furnaces and Carbolite Furnaces

Browse Certified MTP for all the complete line of Lab OvensGrieve Ovens Large Capacity Industrial Bench OvensConvection Ovens and Benchtop OvensVacuum OvensIndustrial Furnace OvensGloves-Heat, and Despatch Ovenskiln for ceramics, including the popular Beaker Tongs, 10in Length

Ignition Oven: A Guide to NCAT Asphalt Content Furnace Tech

Understanding Rolling Thin Film Oven Testing Equipment

Despatch Oven: The Power of Industrial Ovens and Furnaces

Laboratory Convection Oven: Benefits and Applications

The Benefits of a Lab Convection Oven

Gravity Convection Oven: Unlock the Benefits

Replacing a Sheldon Lab Oven Door Gasket

A Guide to Grieve Ovens and Industrial Oven Manufacturing

An Overview Despatch Oven: The Leader in Industrial Ovens

The Ultimate Guide to Industrial Oven Manufacturers

Find the Perfect Heat Treat Oven for Your Needs

Quincy Lab Ovens: Discover the Benefits

Vacuum Oven: Unlocking the Benefits

The Benefits of a Drying Oven for Industrial Applications

The Benefits of Lab Oven for Heating and Drying

What is Pyrolytic Oven Cleaning and Is It Worth it?

Get the Best Lab Oven for Your Research

Field Oven vs Laboratory Oven: Which is More Accurate?

Industrial Oven: Key Considerations

Finding the Perfect Kiln for Ceramics in Lab and Home

Top Oven for Laboratory: Your Guide to Precise Heating

Top Electric Kilns for Ceramics: Find Your Perfect Match

The Lab Incubator: Parts, Working, Types, and Precautions

 

RECOMMENDED FOR YOU

Thermo Scientific Thermolyne FB1315M Benchtop Muffle Furnace, Max. Temp. 2012F, 1.3L 120V

Thermolyne FB1315M Benchtop Muffle Furnace, Max. Temp. 2012F, 1.3L 120V

[]
//Initialize Klaviyo object immediately on page load //Viewed Product